Pay attention to whether there is any abnormal sound from the equipment during operation. If there is any abnormal sound, it must be overhauled, find out the cause and clear the fault. It is strictly forbidden to stand on the equipment when the equipment is running.
Check whether the UV lamp for lid disinfection is turned on, whether ozone is added to the lid of the lid chamber, and whether the pure water pump for lid disinfection has normal water supply. If the filling valve leaks, there are two possibilities: one is that the filling valve is opened but not reset, Second, the sealing ring of the filling valve is not sealed
If there are high caps and crooked caps, there are several situations as follows: First, there is a problem with the fit between the cap and the bottle, and there may be a problem with one of them. Second, the torque of the screw head is not enough. Find out the capping head and increase the torque until it meets the requirements. Third, there is a problem with the bottle loading, mainly at the transition of the star wheel. The bottle protection block may be misaligned and loose, and must be reset.
If the bottle is clamped off during the bottle washing, there are the following situations: First, there is a problem with the bottle on the bottle mouth of the air duct. Just replace it.